Skip to main content
Version: Traxis Camera Tracking 4.0

Prerequisites

Required Camera State​

Before opening Autoprofiler, verify all items below:

  • The correct camera is active and enabled.
  • A live video signal is visible.
  • The tracker is assigned and enabled.
  • The selected camera body reports a current tracked pose.
  • Zoom and focus encoders are connected.
  • Zoom and focus values are normalized and move in the correct direction.
  • The physical lens, camera, and tracking mount are rigid.
  • The project coordinate system and tracking origin are already accepted.
  • At least one reference target has a reliable 3D position.

Use one near target and one far target. Their separation must be meaningful in 3D, not only in the image. Leave at least approximately 1 m between the selected targets since Nodal Offset solving needs useful camera-to-target distance variation; approximately 1 m or more variation is safer.

Video and Detection​

  • The complete Automatic Profiler Tags must remain inside the image.
  • Confirm that digital viewport zoom is not confused with physical lens zoom.

Wide-End Requirement​

Begin a new tracked-camera profile at full wide, with normalized zoom near 0. Camera alignment/offset solving is a wide-end operation. Higher zoom points build optical curves but should not be used to establish the initial tracker-to-camera alignment.

Stop Conditions​

Do not continue if:

  • Tracking is stale or unstable.
  • The wrong tracked object is selected.
  • Zoom or focus jumps unexpectedly.
  • Target coordinate is estimated without measurement.
  • Camera or target moves during a stable capture.